Procedure-SolidSamplesPresstheAnalyzebuttonontheinstrumentscreenagain,theloadingheadslide-blockwillcloseandthelowerelectrodewillopen.Cleantheupperandlowerelectrodemanually,or,ifapplicable,removethecrucibleandpresstheanalyzebuttontocleanwiththeautomaticcleanerAddapproximately0.05gof***GraphitePowdertoa***GraphiteCrucible.Firmlyplacethecrucibleonthelowerelectrodetiporappropriateautoloaderposition.PresstheAnalyzebuttonontheinstrumentscreen,thelowerelectrodewillcloseandtheanalysissequencewillstartandendautomatically上海禹重實(shí)業(yè)有限公司為您提供分析儀,有想法的不要錯(cuò)過(guò)哦!江蘇進(jìn)口力可氧氮?dú)浞治鰞x廠家直銷(xiāo)
力可OHN736&836系列儀器采用惰性熔融法,提供各種無(wú)機(jī)材料、鋼鐵、有色金屬、硬質(zhì)合金陶瓷材料中寬范圍的氧氮?dú)渫瑫r(shí)測(cè)定。ONH836儀器通過(guò)***采納客戶(hù)的反饋意見(jiàn)和創(chuàng)新設(shè)計(jì),力可***儀器采用觸摸屏技術(shù)和在線軟件平臺(tái),增強(qiáng)了儀器的可操作性,降低了分析成本,節(jié)省實(shí)驗(yàn)室桌面空間。用戶(hù)友好界面的Cornerstone?軟件力可的Cornerstone碳硫分析軟件采用觸摸屏界面使用戶(hù)可完整的達(dá)到分析控制、方法設(shè)定、在線診斷、數(shù)據(jù)報(bào)告。Cornerstone碳硫分析軟件允許用戶(hù)在單一分析界面中完成日常的所有工作,快速而且簡(jiǎn)單易用。力可創(chuàng)新的批次和重復(fù)樣品數(shù)據(jù)分組功能極大簡(jiǎn)化了樣品結(jié)果輸出和結(jié)果標(biāo)準(zhǔn)偏差的自動(dòng)計(jì)算。減少了繁瑣的額外數(shù)據(jù)處理。力可分析儀供應(yīng)商分析儀,就選上海禹重實(shí)業(yè)有限公司,讓您滿(mǎn)意,期待您的光臨!
美國(guó)力可LECO氧氮?dú)浞治鰞x公司介紹:美國(guó)力可公司(LECO)始于1936年,以生產(chǎn)用于冶金、機(jī)械、能源、化工、農(nóng)業(yè)、食品及科研開(kāi)發(fā)領(lǐng)域的各種分析儀器。ONH836氧氣/氮?dú)?氫氣元素分析儀設(shè)計(jì)用于使用惰性氣體熔融技術(shù)對(duì)無(wú)機(jī)材料,鐵和非鐵合金以及耐火材料中的氧,氮和氫含量進(jìn)行寬范圍的測(cè)量。堅(jiān)固的樣品加載區(qū)域可簡(jiǎn)化日常維護(hù)并大程度減少大氣污染用于氧氣檢測(cè)的三重紅外電池可實(shí)現(xiàn)業(yè)內(nèi)大的檢測(cè)范圍通過(guò)自動(dòng)化選項(xiàng)提高實(shí)驗(yàn)室生產(chǎn)率可用的自動(dòng)清潔器大程度地減少了兩次分析之間的手動(dòng)清潔需求適用于坩堝和樣品的20位往復(fù)式裝載機(jī)安裝在動(dòng)臂上的觸摸屏界面可提供更好的人體工程學(xué)設(shè)計(jì)和直觀的操作紅外(IR)和熱導(dǎo)率(TC)檢測(cè)器,沒(méi)有活動(dòng)部件,也無(wú)需手動(dòng)調(diào)節(jié)改善TC電池的穩(wěn)定性可繞過(guò)的OMI-2載氣洗滌塔,提高了TC電池的穩(wěn)定性獲得Dyanamic流量補(bǔ)償可進(jìn)一步增強(qiáng)TC細(xì)胞的穩(wěn)定性
MethodSelectionTwomethodsaredescribedinthisapplicationnote;eithermethodcanbeusedtoanalyzeiron,steel,nickel-,andcobalt-basealloys.ThePrecisionMethodisrecommendedforgeneraluseandwillprovidethebestprecisionandaccuracythroughoutthetypicalO,N,andHconcentrationsfoundinthisgroupofmetals;approximatecycletimeis3.5minutes.TheFastTrackmethodcanbeusedwherespeedofanalysisisacriticalcomponent;forexample,whenmoltenmetalisbeingsampledandresultsarerequiredintheshortestpossibletime.Thismethodwillproducesuitableresultsformostsamples;approximatecycletimeis2.25minutes.Asnotedabove,samplingandsamplepreparationarekeyelementstoaccurateO,N,andHdeterminationaswell.Itisuptotheusertodeterminewhichmethodbestmeetstheirneeds.分析儀,就選上海禹重實(shí)業(yè)有限公司,歡迎客戶(hù)來(lái)電!
力可ONH836氧氮?dú)浞治鰞x特點(diǎn)和優(yōu)勢(shì)國(guó)際**的非色散紅外及熱導(dǎo)檢測(cè)器,無(wú)移動(dòng)部件,不需要手動(dòng)調(diào)整采用三個(gè)**的紅外器檢測(cè)氧含量,同時(shí)檢測(cè)CO和CO2,然后在轉(zhuǎn)化為CO2集中檢測(cè),原理上是**完善的,所以不僅可以保證中間量程的測(cè)量精度,在**含量和高含量的檢測(cè)范圍內(nèi)同樣可以滿(mǎn)足精度要求高性能的紅外檢測(cè)器配置***恒溫絕熱技術(shù),消除了外界環(huán)境溫度的干擾長(zhǎng)壽命的紅外發(fā)射光源和無(wú)漂移的電路設(shè)計(jì)保證檢測(cè)器的長(zhǎng)期穩(wěn)定性力可的動(dòng)態(tài)流量補(bǔ)償控制DFC系統(tǒng),保證了流量系統(tǒng)的完善,可以精確控制整個(gè)氣路中的流量,保持流量恒定**改善了材料中氮分析的準(zhǔn)確度可以旁路的OMI-2氣路強(qiáng)化過(guò)濾裝置增強(qiáng)了檢測(cè)器的穩(wěn)定性,使得分析結(jié)果更加準(zhǔn)確可選自動(dòng)功能20位試樣自動(dòng)進(jìn)樣系統(tǒng)通用下電極坩堝支座,容納各種坩堝使用無(wú)需人工干預(yù)的全自動(dòng)清掃系統(tǒng)上海禹重實(shí)業(yè)有限公司為您提供分析儀,歡迎您的來(lái)電哦!美國(guó)力可分析儀廠家直銷(xiāo)
上海禹重實(shí)業(yè)有限公司致力于提供分析儀,歡迎新老客戶(hù)來(lái)電!江蘇進(jìn)口力可氧氮?dú)浞治鰞x廠家直銷(xiāo)
氧氮?dú)浞治鰞x的操作過(guò)程氧氮?dú)浞治鰞x可根據(jù)的用戶(hù)的要求定制。該分析儀配備兩個(gè)不同靈敏度的探測(cè)器,在更多的應(yīng)用中保證了準(zhǔn)確度。操作簡(jiǎn)單而且安全。在樣品稱(chēng)重以后,樣品的重量數(shù)據(jù)通過(guò)電子界面?zhèn)鲗?dǎo)至相連的電腦中,也可以在軟件界面中手動(dòng)輸入樣品的重量。樣品被放置在水平放置的爐子中的低溫區(qū)域。分析開(kāi)始以后,爐子開(kāi)始向上轉(zhuǎn)動(dòng),然后樣品逐漸落入加熱區(qū)。通過(guò)添加載體氣體氮?dú)猓瑲錃獗粩U(kuò)散出來(lái)并且隨載體被傳導(dǎo)至一個(gè)高靈敏度的熱傳導(dǎo)測(cè)量池。通常一次測(cè)量的時(shí)間在3到15分鐘之間。在分析的過(guò)程中設(shè)備可以顯示測(cè)試信號(hào)和設(shè)備的參數(shù),從信號(hào)的評(píng)估到結(jié)果在界面上的顯示全部自動(dòng)完成;而測(cè)量數(shù)據(jù)則被傳導(dǎo)至LIMS(實(shí)驗(yàn)室信息管理系統(tǒng))中。無(wú)需過(guò)多的保養(yǎng)和維護(hù),而除塵器和凈化管的維護(hù)工作也方便。江蘇進(jìn)口力可氧氮?dú)浞治鰞x廠家直銷(xiāo)