山西氧氮?dú)浞治鰞x哪家好

來源: 發(fā)布時(shí)間:2022-02-17

Oxygen,Nitrogen,andHydrogeninRefractoryMetalsSummaryTitaniumisametalthatcanbecombinedwithelementssuchasaluminum,vanadium,molybdenum,andtintoproducehigh-strength,lowdensity,andcorrosion-resistantalloys.Titaniumalloysareusedbythemilitary,medicaldevices,sportinggoods,andaerospaceindustriesbecauseoftheseproperties,andduetothestrictdemandsoftheseindustries,effortneedstobetakentoassurethatthematerialmeetsthehighestofqualitystandards.上海禹重實(shí)業(yè)有限公司分析儀服務(wù)值得放心。山西氧氮?dú)浞治鰞x哪家好

山西氧氮?dú)浞治鰞x哪家好,分析儀

美國LECO力可氧氮?dú)浞治鰞xONH836(氧氮?dú)渎?lián)測儀)系列硬件部分特點(diǎn)和優(yōu)勢(shì)1、爐頭區(qū)域LED照明系統(tǒng)2、爐頭快速拆裝的粉塵過濾裝置3、裝有自動(dòng)旁路閥的可快速拆裝氧水捕集裝置4、的動(dòng)態(tài)流量補(bǔ)償(DFC)保證熱導(dǎo)池氣體流量、壓力恒定5、改進(jìn)的紅外檢測池技術(shù) 新紅外池的恒溫絕熱技術(shù)消除了外界環(huán)境溫度的干擾  長壽命的紅外發(fā)射光源和無漂移的電路設(shè)計(jì)保證紅外檢測池的長期穩(wěn)定  氧高低雙量程采用3個(gè)碳紅外檢測器,同時(shí)檢測一氧化碳和二氧化碳,保證準(zhǔn)確定量  6、高效脈沖爐冷卻系統(tǒng)  強(qiáng)力內(nèi)循環(huán)水冷裝置  雙直流風(fēng)扇保證持續(xù)冷卻,不受電壓波動(dòng)的影響  新電極爐頭設(shè)計(jì),提高脈沖爐熱交換效率  7、全自動(dòng)分析系統(tǒng)(可選)  自動(dòng)清掃裝置  20位或100位全自動(dòng)分析系統(tǒng)  高速全自動(dòng)真空除塵裝置直接將粉塵排至儀器外部捕集器中,消除環(huán)境污染安徽元素分析儀廠家直銷上海禹重實(shí)業(yè)有限公司為您提供分析儀,有需求可以來電咨詢!

山西氧氮?dú)浞治鰞x哪家好,分析儀

SamplePreparationSamplingandsamplepreparationisanimportantissuebecausetraditionalmethodsusedtoobtainsamplesforoxygenandnitrogendeterminationaredifferentfromthoserecommendedforhydrogen,especiallywhensamplingmoltenmetal.Themaindifferenceinsteelsamplingproceduresforoxygen/nitrogenandhydrogenisduetothemobilityofhydrogen.Specialprecautionsmustbeusedwhensamplingforhydrogen.Frommoltensteelandiron,asamplemustbequicklyquenchedincoldwaterandchilledinarefrigerantsuchasliquefiednitrogenoramixtureofacetoneandsolidcarbondioxideinordertoreducelossesofhydrogenfromdiffusion.Lossesofoxygenandnitrogenfromdiffusionarenotaproblem.Asamplethatistakenforhydrogenandchilledinarefrigerantcanalsobeusedforoxygenandnitrogendetermination.However,asamplethatistypicallytakenforoxygenand/ornitrogendeterminationisnotsuitableforhydrogendeterminationduetohydrogenloss(diffusion).Surfacecontaminationmustberemovedbyfilingorlightgrinding,usingcarenottooverheatthesample.

Determinetheinstrumentblank.a.Loginaminimumof3Blankreplicates.b.PresstheAnalyzebuttonontheinstrumentscreen.Afterashortdelay,theloadingheadslide-blockwillopen.c.PresstheAnalyzebuttonontheinstrumentscreenagain,theloadingheadslide-blockwillcloseandthelowerelectrodewillopen.d.Cleantheupperandlowerelectrodemanually,or,ifapplicable,removethecrucibleandpresstheanalyzebuttontocleanwiththeautomaticcleaner.e.Firmlyplaceagraphitecrucibleonthelowerelectrodetip.f.PresstheAnalyzebuttonontheinstrumentscreen,thelowerelectrodewillcloseandtheanalysissequencewillstartandendautomatically.g.Repeatsteps2bthrough2faminimumofthreetimes.h.Settheblankfollowingtheprocedureoutlinedintheoperatorsinstructionmanual.上海禹重實(shí)業(yè)有限公司是一家專業(yè)提供分析儀的公司,歡迎您的來電!

山西氧氮?dú)浞治鰞x哪家好,分析儀

氧氮?dú)浞治鰞x的常見故障及解決方法儀器啟動(dòng)時(shí)顯示。沒有水流。系統(tǒng)分析電流切斷,分析停止。這是水流探測器不正常,水泵不工作,管道堵塞。將儀器的右面板取下,觀察水流探測器,用手?jǐn)D壓補(bǔ)水塑料水瓶,發(fā)現(xiàn)水流正常,顯示正常,證明水流探測器正常,管道暢通。啟動(dòng)循環(huán)水泵,但分析儀顯示沒有水流,此時(shí)可判定水泵不正常。打開水泵轉(zhuǎn)子密封口,啟動(dòng)泵發(fā)現(xiàn)電機(jī)正常運(yùn)轉(zhuǎn),此時(shí)關(guān)閉進(jìn)水,拆下水泵,發(fā)現(xiàn)葉輪脫落。經(jīng)了解,判定是由于外部冷卻水停水,儀器內(nèi)循環(huán)水溫過高(水溫應(yīng)≤70℃),致使葉輪(葉輪材料PVC)熱脹并脫軸。用粘合劑粘合葉輪后再粘于葉輪軸上,待粘合劑凝固后試車,儀器運(yùn)行正常。上海禹重實(shí)業(yè)有限公司為您提供分析儀,期待您的光臨!廣東氧氮?dú)浞治鰞x

上海禹重實(shí)業(yè)有限公司致力于提供分析儀,有想法的不要錯(cuò)過哦!山西氧氮?dú)浞治鰞x哪家好

氧氮?dú)浞治鰞x的常見故障及解決方法供電正常、通訊正常,點(diǎn)擊確認(rèn)鍵后分析儀不工作。這是沒有水流,爐子溫度太高或儀器通道電壓不正常。如沒有水流,爐子溫度太高這些信息會(huì)顯示在顯示器畫面上,但沒有信息顯示說明這兩項(xiàng)正常。接下來檢查儀器通道零位電壓,如果比±3V高出1V以上,可能是因?yàn)闅馄靠樟?,或者是空氣進(jìn)入到分析儀中。檢查并更換化學(xué)試劑,如果有空氣進(jìn)入熱導(dǎo)池里,熱導(dǎo)池的電壓就會(huì)<-6V,此時(shí)打開右面的門,堵住爐子氣體進(jìn)口,10s后,熱導(dǎo)池電壓值必然升高。經(jīng)過逐一排查,**終確認(rèn)堿石棉有問題,更換后儀器正常。山西氧氮?dú)浞治鰞x哪家好